DCN NE number overload start. (NeNumber=[NeNumber])
The number of NEs connected to the GNE exceeds the alarm threshold.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwIpRanDcnNeNumberOverLoad |
Trap OID |
1.3.6.1.4.1.2011.5.25.300.1.3.1 |
MIB |
HUAWEI-IPRAN-DCN-MIB |
Alarm ID |
0x0001009b |
Alarm Name |
hwIpRanDcnNeNumberOverLoad |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DCNM_1.3.6.1.4.1.2011.5.25.300.1.3.2 hwIpRanDcnNeNumberOverLoadRecovery |
Parameter | Description |
---|---|
NeNumber |
Indicates the NE quantity. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.300.1.2.1 |
hwIpRanDcnNeNumber |
- |
1. Run the display dcn ne-info command to check whether the number of entries in the DCN core routing table has exceeded the upper limit.
2. Run the display this command in the DCN view to check the alarm threshold for the number of NEs connected to the GNE.
3. Collect alarm information and configuration information, and then contact technical support personnel. Replan the DCN subnets or change the alarm threshold for the number of NEs connected to the GNE.