DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.15 hwEntityCheckFail-68142

Trap Buffer Description

Physical is detected failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=68142, BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Power_BackPlane is failed, the number of pm on two plane is different)

Physical entity is detected failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwEntityCheckFail

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.15

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x0813005d

Alarm Name

hwEntityCheckFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.16 hwEntityCheckResume-68142

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

indicates the severity level of the trap reported to the NMS.

BaseTrapProbableCause

Indicates the possible cause of the trap.

BaseTrapEventType

Indicates the trap type.

EntityPhysicalIndex

Physical index. The physical index varies with the chassis ID.

EntPhysicalContainedIn

Indicates the parent index.

EntPhysicalName

Indicates the name of the entity such as a chassis.

RelativeResource

Indicates the name of the part related to the trap.

ReasonDescription

Indicates the description of the possible cause.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

Services will not be affected.

Possible Causes

The two power supply planes have different number of PMs.

Procedure

1. Check the number of PMs installed on each power supply plane and install more PMs on the plane with less PMs to ensure that the two planes have the same number of PMs. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If the alarm persists, go to Step 2.

2. Collect alarm, log, and configuration information, and contact technical support personnel.

3. End.