DEVM_1.3.6.1.4.1.2011.5.25.157.2.117 hwLoopbackAlarm

Trap Buffer Description

Port Loopback Alarm! (InterfaceIndex=[InterfaceIndex], InterfaceName=[InterfaceName], LoopType=[LoopType])

Port loopback alarm.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwLoopbackAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.117

MIB

HUAWEI-PORT-MIB

Alarm ID

0x09490029

Alarm Name

hwLoopbackAlarm

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.157.2.118 hwLoopbackAlarmResume

Trap Buffer Parameters

Parameter Description

InterfaceIndex

Index of physical port.

InterfaceName

Name of physical port.

LoopType

loopback type.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1

hwPhysicalPortIfIndex

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4

hwPhysicalPortName

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.13

hwPhysicalLoopbackType

hwPhysicalPortIfIndex

Impact on the System

Services on the interface or path will be interrupted.

Possible Causes

An interface loopback was configured.

Procedure

1.Remove the loopback, and the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm is not cleared, go to Step 2.

2.Collect alarm information, log information and configuration information, and then contact technical support personnel.

3.End.