Output error alarm.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],BoardID=[hwPhysicalPortInSlot],CardID=[hwPhysicalPortInCard],PortID=[hwPhysicalPortInPort],InterfaceName=[hwPhysicalPortName])
An alarm is generated when the number of alarms is set higher than the set time.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwPhysicalPortOutputError |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.155 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x08130076 |
Alarm Name |
hwOutputErrorAlarm |
Alarm Type |
processingErrorAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.157.2.156 hwOutputErrorAlarmResume |
Parameter | Description |
---|---|
hwPhysicalPortIfIndex |
Interface index(es) of physical port(s) present on the device. |
hwPhysicalPortInSlot |
Slot ID |
hwPhysicalPortInCard |
Card ID |
hwPhysicalPortInPort |
Port ID |
hwPhysicalPortName |
Port name |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.6 |
hwPhysicalPortInSlot |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.7 |
hwPhysicalPortInCard |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.8 |
hwPhysicalPortInPort |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
1.Replace the optical module and check whether the alarm is cleared.
2.Replace the fiber, check whether the alarm is cleared.
3.Collect the alarm information, log information, and configuration information, and then contact technical support personnel.
4.End.