The local fault alarm of FlexE physical interface has occurred.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex], hwPhysicalPortName=[hwPhysicalPortName])
The local fault alarm of FlexE physical interface has occurred.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Error |
Mnemonic Code |
hwFlexEPhyLocalFaultAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.270 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x00F101d9 |
Alarm Name |
hwFlexEPhyLocalFaultAlarm |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.157.2.271 hwFlexEPhyLocalFaultAlarmResume |
Parameter | Description |
---|---|
hwPhysicalPortIfIndex |
Index of physical port. |
hwPhysicalPortName |
Name of physical port. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1 |
hwPhysicalPortIfIndex |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
1.Check whether the connected FlexE physical interfaces all work in FlexE mode.
2.Switch the connected FlexE physical interface to FlexE mode. Then check whether the alarm is cleared.
3.Collect alarm information, log information and configuration information, and then contact technical support personnel.
4.End.