DEVM_1.3.6.1.4.1.2011.5.25.157.2.41 hwPaisAlarm

Trap Buffer Description

Indication signal in the higher order path alarm.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex],BoardID=[hwPhysicalPortInSlot],CardID=[hwPhysicalPortInCard],PortID=[hwPhysicalPortInPort],HpID=[hwSDHHpPerfCurrentHpIndex],InterfaceName=[hwPhysicalPortName])

Indication signal in the higher order path alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwPaisAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.41

MIB

HUAWEI-PORT-MIB

Alarm ID

0x0813008a

Alarm Name

hwPaisAlarm

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.157.2.42 hwPaisAlarmResume

Trap Buffer Parameters

Parameter Description

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortInSlot

Slot ID.

hwPhysicalPortInCard

Card ID.

hwPhysicalPortInPort

Port ID.

hwSDHHpPerfCurrentHpIndex

High-order path ID.

hwPhysicalPortName

Name of physical port.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.6

hwPhysicalPortInSlot

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.7

hwPhysicalPortInCard

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.8

hwPhysicalPortInPort

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.3.2

hwPortPhysicalHpIndex

-

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4

hwPhysicalPortName

hwPhysicalPortIfIndex

Impact on the System

A service switchover or interruption will occur.

Possible Causes

  • Cause 0: The optical fiber was broken.
  • Cause 1: The optical loss was beyond the normal range.
  • Cause 2: The remote device failed to send the optical signal.
  • Cause 3: The cross-connect board of the remote device failed, was not installed, or was not installed properly.
  • Cause 4: The clock board of the remote device failed.

Procedure

1.Check whether any optical fiber is connected to the optical interface. If no optical fiber is used, shut down the laser of the optical interface and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

2.Check whether the optical fiber is broken. If the optical fiber is broken, replace the optical fiber and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

3.Check whether the receive optical power of the local device is less than the minimum value. If the receive optical power is less than the minimum value, clean the optical fiber connector and the optical interface on the interface board. Check that the flange and the optical attenuator are properly connected and the optical attenuator value is in the normal range. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

4.Check whether the receive optical power of the local device is high. If the receive optical power is greater than the maximum value, increase the attenuation value to adjust the receive optical power to the normal range and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

5.Check whether the laser on the corresponding interface board of the remote device is shut down. If the laser is shut down, switch on the laser and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

6.Check whether the transmit optical power is proper on the remote device. If the transmit optical power is proper, replace the corresponding interface board and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

7.Check whether the clock board of the remote device fails. If the clock board fails, replace the clock board and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

8.Check whether the interface board of the local device where the alarm was generated fails. If the interface board fails, replace the interface board and check whether the alarm is cleared.

  • If the alarm is cleared, go to End.
  • If the alarm persists, go to Step 9.

9.Collect alarm information, log information and configuration information, and then contact technical support personnel.