DEVM_1.3.6.1.4.1.2011.5.25.219.2.13.1 hwUserDefAlarm

Trap Buffer Description

The User define alarm has been detected. (EntityPhysicalIndex=[EntityPhysicalIndex],EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName="[EntPhysicalName]", UserDefAlarmName="[UserDefAlarmName]",UserDefChannel=[UserDefChannel])

The user defined alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwUserDefAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.13.1

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813210f

Alarm Name

hwUserDefAlarm

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.13.2 hwUserDefResume

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the physical index.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

Name of a physical entity.

UserDefAlarmName

Name of the user-defined alarm.

UserDefChannel

Monitoring channel of the user-defined alarm.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.6

hwUserDefAlarmName

-

1.3.6.1.4.1.2011.5.25.219.1.7

hwUserDefChannel

-

Impact on the System

Services are not affected.

Possible Causes

The ambient environment condition, such as temperature, voltage, access sensor, or humidity did not comply with environment standards.

Procedure

1. Change the ambient environment, such as temperature, voltage, access sensor, and humidity, to make them comply with environment standards.

2. Collect the alarm information, log information, and configuration information, and contact technical support personnel.

3. End.