DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid-132621

Trap Buffer Description

The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132621, Reason=The control bus of the board is abnormal.)

The overall function of the board does not take effect.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813002e

Alarm Name

hwBoardInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.6 hwBoardInvalidResume-132621

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The SC chip of SFU cannot be accessed. Packet loss will occur when the SFU forwards data.

Possible Causes

The control bus of the board is abnormal.

Procedure

1. Run the reset slot slot-id command to reset the faulty SFU. After the SFU is registered, check whether the alarm is cleared.

  • If so, go to Step 4.
  • If not, go to Step 2.

2. Replace the SFU and check whether the alarm is cleared.

  • If so, go to Step 4.
  • If not, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.