DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid-132670

Trap Buffer Description

The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132670, Reason=The user-input supply power of the board is insufficient.)

The overall function of the board does not take effect.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813002e

Alarm Name

hwBoardInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.6 hwBoardInvalidResume-132670

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The power supply failure may lead to power supply insufficiency, which may cause board resetting. This indirectly affects services, and therefore this problem needs to be solved.

Possible Causes

The user-input supply power of the board is insufficient.

Procedure

1. Check whether the device is equipped with sufficient power modules.

  • If power modules are sufficient, go to Step 2.
  • If power modules are not sufficient, go to Step 3.

2. Check whether the maximum power consumption allowed is too small.

  • If the maximum power consumption allowed is too small, change it to a proper value and then go to Step 4.
  • If the maximum power consumption allowed is not too small, go to Step 5.

3. Install extra power modules.

4. Check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 6.
  • If the alarm persists, go to Step 5.

5. Collect trap, log, and configuration information, and contact technical support.

6. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >