DEVM_1.3.6.1.4.1.2011.5.25.219.2.9.1 hwCommunicateError-140304

Trap Buffer Description

The communication channel failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=140304, EntityCommunicateType=[EntityCommunicateType], Reason=The I2C control bus on the backplane malfunctions.)

The physical entity channel is faulty.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwCommunicateError

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.9.1

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130011

Alarm Name

hwCommunicateError

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.9.2 hwCommunicateResume-140304

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntityTrapFaultID

To describe the fault id of trap.

EntPhysicalName

The textual name of the physical entity.

EntityTrapEntType

The type of this entity.

EntityCommunicateType

The type of this commnuicate.

The value can be:

1. Control channel:1.

2. monitor channel:2.

3. clock channel:3.

4. data channel:4.

Reason

Reason integer.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.4

hwEntityCommunicateType

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

Impact on the System

1. The backplane elabel cannot be read.

2. The fan base information and elabel cannot be read.

Possible Causes

The I2C control bus on the backplane malfunctions.

Procedure

1. Replace the involved subcard in the coprresponding slot.

2. If the fault persists, replace the main control board in the slot.

3. If the fault persists, replace the chassis.

4. Collect the information about alarms, logs, and configurations, and then contact Huawei technical support personnel.