The actual bandwidth is less than the configured bandwidth.(hwPortIfIndex=[hwPortIfIndex], hwPortName=[hwPortName], hwPortBW=[hwPortBW])
The actual bandwidth is less than the configured bandwidth.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwFlexEBwReduceAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.266 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
0x00F10226 |
Alarm Name |
hwFlexEBwReduceAlarm |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DRIVER_1.3.6.1.4.1.2011.5.25.157.2.267 hwFlexEBwReduceAlarmResume |
Parameter | Description |
---|---|
hwPortIfIndex |
Index of port. |
hwPortName |
Name of port. |
hwPortBW |
The bandwidth of port. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1 |
hwPhysicalPortIfIndex |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.37 |
hwPhysicalPortBW |
hwPhysicalPortIfIndex |
1. Check link state of all FlexE physical interfaces in the group which this FlexE interface bounded, and recover link state of physical interfaces. Then check whether the alarm is cleared.
2.Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.