The sub-timeslot granula of the butted FlexE interfaces is different.(hwPortIfIndex=[hwPortIfIndex], hwPortName=[hwPortName])
The sub-timeslot granularities of the FlexE interfaces are different.
| Trap Attribute | Description | 
|---|---|
| Alarm or Event | Alarm | 
| Trap Severity | Error | 
| Mnemonic Code | hwFlexESubTimeSlotMismatch | 
| Trap OID | 1.3.6.1.4.1.2011.5.25.157.2.278 | 
| MIB | HUAWEI-PORT-MIB | 
| Alarm ID | 0x00F10232 | 
| Alarm Name | hwFlexESubTimeSlotMismatch | 
| Alarm Type | equipmentAlarm | 
| Raise or Clear | Raise | 
| Match trap | DRIVER_1.3.6.1.4.1.2011.5.25.157.2.279 hwFlexESubTimeSlotMismatchResume | 
| Parameter | Description | 
|---|---|
| hwPortIfIndex | Index of port. | 
| hwPortName | Name of port. | 
| VB OID | VB Name | VB Index | 
|---|---|---|
| 1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1 | hwPhysicalPortIfIndex | hwPhysicalPortIfIndex | 
| 1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 | hwPhysicalPortName | hwPhysicalPortIfIndex | 
1. Configure the same sub-timeslot granularity, and then check whether the alarm is cleared.
2. Collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.