FEI_IFIT_OM_1.3.6.1.4.1.2011.5.25.364.2.1.1 hwIfitStaticFlowNumExceedAlarm

Trap Buffer Description

The total number of iFIT static flows and reverse flows in LC board reaches the upper limit. (SlotId=[SlotId],FlowLimitNum=[FlowLimitNum])

The total number of iFIT static flows and reverse flows in LC board reaches the upper limit.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwIfitStaticFlowExceedSpecThreshold

Trap OID

1.3.6.1.4.1.2011.5.25.364.2.1.1

MIB

HUAWEI-IFIT-MIB

Alarm ID

0x00f10397

Alarm Name

hwIfitStaticFlowExceedSpecThreshold

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

FEI_IFIT_OM_1.3.6.1.4.1.2011.5.25.364.2.1.2 hwIfitStaticFlowNumExceedResume

Trap Buffer Parameters

Parameter Description

SlotId

The number of LC board.

FlowLimitNum

The maximum number of iFIT instances on this LC board.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.364.1.1.1.1.1

hwIfitFlowExceedBoard

hwIfitFlowExceedBoard

hwIfitMaxFlowInBoard

1.3.6.1.4.1.2011.5.25.364.1.1.1.1.2

hwIfitMaxFlowInBoard

hwIfitFlowExceedBoard

hwIfitMaxFlowInBoard

Impact on the System

New iFIT static flows and reverse flows will not apply.

Possible Causes

The number of iFIT static flows and reverse flows in LC board reaches the upper limit.

Procedure

Try to reduce the number of iFIT static flows and reverse flows in LC.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >