FEI_L2_1.3.6.1.4.1.2011.5.25.41.4.60 hwModeChannelBandwidthAlarm

Trap Buffer Description

The total bandwidth of the channelized sub-interfaces on the same physical or Eth-Trunk interface has exceeded the maximum available bandwidth of the physical or Eth-Trunk interface. (Interface=[IfIndex], Bandwidth=[Bandwidth], SubIfBandwidthSum=[SubIfBandwidthSum], InterfaceName=[InterfaceName])

The total bandwidth of the channelized sub-interfaces on the same physical or Eth-Trunk interface has exceeded the maximum available bandwidth of the physical or Eth-Trunk interface.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwModeChannelBandwidthAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.41.4.60

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x00F102af

Alarm Name

hwModeChannelBandwidthAlarm

Alarm Type

processingErrorAlarm

Raise or Clear

Raise

Match trap

FEI_L2_1.3.6.1.4.1.2011.5.25.41.4.61 hwModeChannelBandwidthResume

Trap Buffer Parameters

Parameter Description

IfIndex

Interface index

Bandwidth

available bandwidth of the physical or Eth-Trunk interface

SubIfBandwidthSum

The total bandwidth of the channelized sub-interfaces

InterfaceName

Interface name

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.25.1.1.1

hwModeChannelBandwidthIfIndex

hwModeChannelBandwidthIfIndex

1.3.6.1.4.1.2011.5.25.41.1.25.1.1.2

hwModeChannelBandwidthValue

hwModeChannelBandwidthIfIndex

1.3.6.1.4.1.2011.5.25.41.1.25.1.1.3

hwModeChannelSubIfBandwidthSum

hwModeChannelBandwidthIfIndex

1.3.6.1.4.1.2011.5.25.41.1.25.1.1.4

hwModeChannelIfName

hwModeChannelBandwidthIfIndex

Impact on the System

Higher bandwidth cannot be configured for the channelized sub-interfaces.

Possible Causes

The total bandwidth of the channelized sub-interfaces on the same physical or Eth-Trunk interface has exceeded the maximum available bandwidth of the physical or Eth-Trunk interface.

Procedure

1. Run the mode channel bandwidth command in the sub-interface view to set the bandwidth of the channelized sub-interface to a smaller value. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If the alarm persists, go to Step 2.

2. Collect the trap information, log information, and configuration information, and then contact technical support personnel.

3. End.