The state of interface changed from suppress to unsuppress. (InterfaceName=[InterfaceName], SuppressState=[SuppressState])
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Warning |
Mnemonic Code |
hwIfDampInterfaceAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.41.3.56 |
MIB |
HUAWEI-IF-EXT-MIB |
Alarm ID |
0X0852201B |
Alarm Name |
hwIfDampSuppress |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Clear |
Match trap |
Parameter | Description |
---|---|
InterfaceName |
Interface name |
SuppressState |
Interface suppression status:
|
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1.3.6.1.4.1.2011.5.25.41.1.1.1.1.41 |
hwIFExtDampStatus |
hwIFExtIndex |
Cause 1: The interface was added to a VS.Cause 2: The interface is offline.Cause 3: The suppression penalty value of the interface fell below the reuse value.Cause 4: The interface suppression function is disabled in system view or interface view.Cause 5: The damp-interface level configuration was changed.Cause 6: The damp-interface enable command was run in the system view, and the damp-interface ignore-global command was run in the interface view, which cleared related alarms on the interface.Cause 7: The damp-interface enable command was run in the system view, and the damp-interface enable command was run in the interface view, which cleared related alarms on the interface. The physical status suppression configurations on the interface takes precedence over the global configurations.Cause 8: The shutdown and undo shutdown commands were run in sequence on the local interface.