The tunnel receives a RDI alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], IfIndex=[IfIndex], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], IfName=[IfName], SignalledTunnelName=[SignalledTunnelName])
The peer end of an MPLS tunnel detected an LOC alarm and notified the local end of the LOC alarm.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Error |
Mnemonic Code |
hwMplsOamRdi |
Trap OID |
1.3.6.1.4.1.2011.5.25.121.2.1.22 |
MIB |
HUAWEI-MPLS-EXTEND-MIB |
Alarm ID |
0x0001005a |
Alarm Name |
hwMplsOamRdi |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.23 hwMplsOamRdiRecovery |
Parameter | Description |
---|---|
SessionTunnelId |
Tunnel ID |
LocalLspId |
Local LSP ID |
IngressLsrId |
ID of the ingress LSR |
EgressLsrId |
ID of the egress LSR |
IfIndex |
Index of the interface |
TunnelName |
Tunnel name |
SgnlPrtcl |
Tunneling protocol Ranges:
|
IfName |
The name of the interface |
LsrRole |
Lsp Lsr Role. |
SignalledTunnelName |
Tunnel alias. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.121.1.1.1.29 |
hwMplsTunnelInterfaceName |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1.3.6.1.4.1.2011.5.25.121.1.1.1.30 |
hwMplsTunnelSignalProto |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1.3.6.1.4.1.2011.5.25.121.1.1.1.33 |
hwMplsTunnelSignalledTunnelName |
hwMplsTunnelIndex hwMplsTunnelInstance hwMplsTunnelIngressLSRId hwMplsTunnelEgressLSRId |
1. Run the display mpls-tp oam meg meg-name command to check whether the CC function is correctly configured on the ingress and egress MEGs.
2. Reconfigure the CC function on the ingress and egress MEGs.
3. Run the display interface command to check whether any physical interface connected to the MPLS tunnel is shut down.
4. Run the undo shutdown command to enable the physical interface. Then check whether the alarm is cleared.
5. If all configurations are correct, the MPLS tunnel is faulty. Then go to Step 7.
6. Collect alarm information and configuration information, and then contact technical support personnel.
7. End.