MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.69 hwMplsDynamicLabelTotalCountExceed

Trap Buffer Description

The dynamic label count reaches the upper limit. (hwMplsDynamicLabelTotalCount=[DynamicLabelTotalCount], hwMplsDynamicLabelCurrentCount=[DynamicLabelCurrentCount])

Dynamic label usage reached 100%.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwMplsDynamicLabelTotalCountExceed

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.69

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00F10033

Alarm Name

hwMplsDynamicLabelTotalCountExceed

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.70 hwMplsDynamicLabelTotalCountExceedClear

Trap Buffer Parameters

Parameter Description

DynamicLabelTotalCount

Indicates the maximum number of dynamic labels supported by the device.

DynamicLabelCurrentCount

Indicates the number of dynamic labels that are currently used on the device.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.3.3

hwMplsDynamicLabelTotalCount

-

1.3.6.1.4.1.2011.5.25.121.3.4

hwMplsDynamicLabelCurrentCount

-

Impact on the System

All dynamic labels are used, and no subsequent LSPs can be established.

Possible Causes

A great number of LSPs were established, and all dynamic labels were used.

Procedure

1. Run the display mpls lsp statistics command to view statistics about LSPs. Re-plan the services and delete unwanted LSPs that use dynamic labels. Then check whether MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.70 hwMplsDynamicLabelTotalCountExceedClear is generated.

  • If this clear alarm is generated, go to step 3.
  • If this clear alarm is not generated, go to step 2.

2. Collect alarm information and configuration information, and then contact technical support personnel.

3. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >