MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.79 hwMplsTunnelHotstandbySwitch

Trap Buffer Description

Traffic switched from the primary LSP to the hot-standby LSP.(SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], TunnelName=[TunnelName], SignalledTunnelName=[SignalledTunnelName])

Traffic was switched from the primary LSP to the hot-standby LSP.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwMplsTunnelHotstandbySwitch

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.79

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00F101bb

Alarm Name

hwMplsTunnelHotstandbySwitch

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.80 hwMplsTunnelHotstandbyResume

Trap Buffer Parameters

Parameter Description

SessionTunnelId

Session tunnel ID

LocalLspId

Local LSP ID

IngressLsrId

Ingress LSR ID

EgressLsrId

Egress LSR ID

TunnelName

Tunnel name

SignalledTunnelName

User-Defined Tunnel Name

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.1.1.1.29

hwMplsTunnelInterfaceName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.33

hwMplsTunnelSignalledTunnelName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

Impact on the System

Services will not be affected.

Possible Causes

The primary LSP went Down, and the hot-standby LSP was working properly.

Procedure

  • Check that the primary LSP is working properly.