MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.87 hwMplsOamFDI

Trap Buffer Description

The tunnel receives an FDI alarm. (SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId], IfIndex=[IfIndex], TunnelName=[TunnelName], SignalingProtocol=[SgnlPrtcl], IfName=[IfName], SignalledTunnelName =[SignalledTunnelName])

An FDI alarm was generated on the tunnel.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

MPLS_TUNNEL_FDI

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.87

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00010053

Alarm Name

hwMplsOamFDI

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.88 hwMplsOamFDIRecovery

Trap Buffer Parameters

Parameter Description

SessionTunnelId

Tunnel Id

LocalLspId

Local Lsp Id

IngressLsrId

Ingress Lsr Id

EgressLsrId

Egress Lsr Id

IfIndex

Interface Index

TunnelName

Tunnel Name

SgnlPrtcl

Tunnel Signal Protocol

Ranges:

  • 1:RSVP
  • 2:STATIC
  • 3:CRSTATIC

IfName

Interface Name

TunnelDirection

Tunnel Direction

SignalledTunnelName

User-Defined Tunnel Name

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.1.1.1.29

hwMplsTunnelInterfaceName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.30

hwMplsTunnelSignalProto

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.1.1.1.32

hwMplsTunnelDirection

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

1.3.6.1.4.1.2011.5.25.121.1.1.1.33

hwMplsTunnelSignalledTunnelName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

Impact on the System

Services may be interrupted.

Possible Causes

The upstream P device detected a failure at the physical layer, for example, a fiber cut.

Procedure

1. Check that no fault (for example, optical fiber disconnect) occurs at the physical layer of each upstream node.

  • If such a fault does not exist, go to Step 3.
  • If such a fault exists, go to Step 2.

2. Rectify the fault on the physical layer of the upstream node by replacing the faulty component. Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect log information and configuration information, and then contact technical support personnel.

4. End.