MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.89 hwP2mpTeTunnelDown

Trap Buffer Description

P2MP tunnel status changes to down.(SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], P2mpId=[P2mpId], TunnelName=[TunnelName], Reason=[DownReason])

A P2MP tunnel went Down.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwP2mpTeTunnelDown

Trap OID

1.3.6.1.4.1.2011.5.25.121.2.1.89

MIB

HUAWEI-MPLS-EXTEND-MIB

Alarm ID

0x00F10265

Alarm Name

hwP2mpTeTunnelDown

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

MPLS_LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.90 hwP2mpTeTunnelDownClear

Trap Buffer Parameters

Parameter Description

SessionTunnelId

Tunnel Id

LocalLspId

Local Lsp Id

IngressLsrId

Ingress Lsr Id

P2mpId

P2MP Id

TunnelName

Tunnel Name

DownReason

Alarm reason. Range: (10, 30, 100) - 10: Tunnel Shutdown - 30: All Sub Lsp Down - 100: Alarm Clear

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.121.1.1.1.29

hwMplsTunnelInterfaceName

hwMplsTunnelIndex

hwMplsTunnelInstance

hwMplsTunnelIngressLSRId

hwMplsTunnelEgressLSRId

1.3.6.1.4.1.2011.5.25.121.2.2.20

hwMplsP2mpId

-

1.3.6.1.4.1.2011.5.25.121.2.2.3

hwMplsTunnelDownReason

-

Impact on the System

Traffic forwarded along the tunnel will be interrupted.

Possible Causes

  • Cause 10: The tunnel was manually shut down.
  • Cause 30: P2MP Tunnel All Sub Lsp Down.

Procedure

  • Cause 10: The tunnel was manually shut down.

    1. Run the undo shutdown command on the tunnel interface view. - If the fault is rectified, go to Step 3. - If the fault persists, go to Step 2. 2. Collect log information and configuration information, and then contact technical support personnel. 3. End.

  • Cause 30: P2MP Tunnel All Sub Lsp Down.

    The same as Cause 10.