The MSTP process's port has been set to forwarding state. (ProcessID=[ProcessID], InstanceID=[InstanceID], PortID1=[PortID1], PortID2=[PortID2], PortID3=[PortID3], PortID4=[PortID4], PortIDFlag=[PortIDFlag], PortState=[PortState], IfIndex=[IfIndex], PortName=[PortName], PwName=[PwName])
Specify that the status of the port STP becomes Forwarding in MSTP process
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
PROPORT_STATE_FORWARDING |
Trap OID |
1.3.6.1.4.1.2011.5.25.42.4.2.18 |
MIB |
HUAWEI-MSTP-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
ProcessID |
Indicates the MSTP process ID. |
InstanceID |
Indicates the instance ID. |
PortID1 |
Indicates ID 1 of the port in the MSTP process. |
PortID2 |
Indicates ID 2 of the port in the MSTP process. |
PortID3 |
Indicates ID 3 of the port in the MSTP process. |
PortID4 |
Indicates ID 4 of the port in the MSTP process. |
PortIDFlag |
Indicates the port flag. |
PortState |
Indicates the port state. |
IfIndex |
Indicates the interface index. |
PortName |
Indicates the port name. |
PwName |
Indicates the PW name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.42.4.1.29.1.1 |
hwMstpProNewPortState |
hwMstpProID hwMstpInstanceID hwMstpPortId1 hwMstpPortId2 hwMstpPortId3 hwMstpPortId4 hwMstpPortIdFlag |
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1.3.6.1.4.1.2011.5.25.42.4.1.33 |
hwMstpPwName |
- |
1. View physical devices on the network to check whether a new physical link that has STP enabled is added.
2. Check whether the added physical link is necessary.
3. Run the display stp command to check whether the interfaces are consistent with the STP calculation results.
4. Correctly deploy the network topology, and then check whether the alarm is cleared. If the alarm persists, go to Step 5.
5. Collect trap, log, and configuration information, and then contact technical support personnel.