The loop protection port in the instance of the MSTP process did not receive BPDU packets within prescriptive time. (ProcessID=[ProcessID], InstanceID=[InstanceID], PortID1=[PortID1], PortID2=[PortID2], PortID3=[PortID3], PortID4=[PortID4], PortIDFlag=[PortIDFlag], PortState=[PortState], IfIndex=[IfIndex], PortName=[PortName], PwName=[PwName])
Specify that the root port has not received any BPDU packets for a long time when loop protection is enabled
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
PROPORT_LOOP_GUARDED |
Trap OID |
1.3.6.1.4.1.2011.5.25.42.4.2.23 |
MIB |
HUAWEI-MSTP-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
ProcessID |
Indicates the MSTP process ID. |
InstanceID |
Indicates the instance ID. |
PortID1 |
Indicates ID 1 of the port in the MSTP process. |
PortID2 |
Indicates ID 2 of the port in the MSTP process. |
PortID3 |
Indicates ID 3 of the port in the MSTP process. |
PortID4 |
Indicates ID 4 of the port in the MSTP process. |
PortIDFlag |
Indicates the port flag. |
PortState |
Indicates the port state. |
IfIndex |
Indicates the interface index. |
PortName |
Indicates the port name. |
PwName |
Indicates the PW name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.42.4.1.29.1.1 |
hwMstpProNewPortState |
hwMstpProID hwMstpInstanceID hwMstpPortId1 hwMstpPortId2 hwMstpPortId3 hwMstpPortId4 hwMstpPortIdFlag |
1.3.6.1.2.1.31.1.1.1.1 |
ifName |
ifIndex |
1.3.6.1.4.1.2011.5.25.42.4.1.33 |
hwMstpPwName |
- |
1. Run the display stp command to check whether STP is disabled on the interfaces that are directly connected.
2. Run the stp enable command in the interface view to enable STP. Then, check whether the alarm is cleared. If the alarm persists, go to Step 3.
3. Collect alarm information and configuration information, and then contact technical support personnel.
1. Check whether the link is congested between the local device and the neighbor device.
2. Repair the physical link and then check whether the alarm is cleared. If the alarm persists, go to Step 3.