CGN session resources ran out. (SessionNumber=[SessionNumber],Slot=[Slot], Cpu=[Cpu])
The number of NAT session connections reaches the upper limit.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwCGNSessionExhaustAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.240.2.22 |
MIB |
HUAWEI-DSLITE-MIB |
Alarm ID |
0x00F10016 |
Alarm Name |
hwCGNSessionExhaustAlarm |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
NAT_1.3.6.1.4.1.2011.5.25.240.2.23 hwCGNSessionExhaustResumeAlarm |
Parameter | Description |
---|---|
SessionNumber |
Number of established sessions. |
Slot |
Slot ID of a service board. |
Cpu |
CPU ID of the service board. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.240.1.2.12 |
hwCGNAlarmSessionNum |
- |
1.3.6.1.4.1.2011.5.25.240.1.2.10 |
hwVSUAlarmSlot |
- |
1.3.6.1.4.1.2011.5.25.240.1.2.11 |
hwVSUAlarmCpu |
- |
1.Run the display nat session table command to view NAT sessions established on a NAT device. Check whether the number of established NAT sessions reaches the maximum number.
2.Collect trap, log, and configuration information, and then contact technical support personnel.