PIM_1.3.6.1.4.1.2011.5.25.149.4.0.21 routeThresholdExceed

Trap Buffer Description

The number of existed routing entries exceeded the global upper threshold. (LimitType=[LimitType], AddressFamily=[AddressFamily], CurrentCount=[CurrentCount], LimitCount=[LimitCount], ThresholdCount=[ThresholdCount], ReasonType=[ReasonType])

The percentage ratio of created PIM entries on the device to the specified limit reached the alarm trigger threshold.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

PIM_ROUTE_THRESHOLD

Trap OID

1.3.6.1.4.1.2011.5.25.149.4.0.21

MIB

HUAWEI-PIM-STD-MIB

Alarm ID

0x00F100ef

Alarm Name

PIM_ROUTE_THRESHOLD

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.22 routeThresholdExceedClear

Trap Buffer Parameters

Parameter Description

LimitType

Type of entry for which an entry number limit takes effect, which is one of the followings:

  • 1:PIM-SM (*, G) entry
  • 2:PIM-SM (S, G) entry
  • 3:PIM-DM (*, G) entry
  • 4:PIM-DM (S, G) entry

AddressFamily

Address family

CurrentCount

Number of created PIM entries on the device

LimitCount

Limit on the number of PIM entries on the device

ThresholdCount

Threshold at which the alarm is generated

ReasonType

Alarm cause, which is one of the followings:

  • Entries are changed.
  • The configuration is changed.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.149.4.1.74

hwPimNotificationLimitType

-

1.3.6.1.4.1.2011.5.25.149.4.1.62

hwPimNotificationAddressType

-

1.3.6.1.4.1.2011.5.25.149.4.1.72

hwPimNotificationTypeTotalCount

-

1.3.6.1.4.1.2011.5.25.149.4.1.75

hwPimNotificationLimitUpperThreshold

-

1.3.6.1.4.1.2011.5.25.149.4.1.78

hwPimNotificationThresholdReasonType

-

Impact on the System

When the alarm is generated, new entries can still be created, but the specified limit may be reached.

Possible Causes

  • Cause 1: Entry create
  • Cause 2: Configuration change

Procedure

  • Cause 1: Entry create

    1. Run the display multicast global outgoing-interface pim sm statistics command to check whether the alarm trigger threshold or the number limit is low.

    • If either the alarm trigger threshold or the number limit is low, go to Step 2.
    • If the alarm trigger threshold and the number limit are not low, go to Step 3.

    2. Run the multicast global limit command to modify the alarm trigger threshold or the number limit. Then, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.
    • If the alarm persists, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

    4. End.

  • Cause 2: Configuration change

    The same as Cause 1.

Copyright © Huawei Technologies Co., Ltd.