PTP_1.3.6.1.4.1.2011.5.25.187.5.1 hwPtpPortStateChange

Trap Buffer Description

The port status changes. (hwPtpPortIfIndex=[hwPtpPortIfIndex], hwPtpPortName=[hwPtpPortName], hwPtpPortState=[hwPtpPortState], hwPtpOldPortState=[hwPtpOldPortState])

An alarm is generated when the port status changes.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwPtpPortStateChange

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.1

MIB

HUAWEI-PTP-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

hwPtpPortIfIndex

Port index.

hwPtpPortName

Name of the port whose status changes.

hwPtpPortState

Current status of the port.

hwPtpOldPortState

Old status of a port.

The value can be:

master(1)

slave(2)

passive(3)

listening(4)

faulty(5)

initializing(6)

premaster(7)

disabled(8)

uncalibrated(9)

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.2.1.1.43

hwPtpPortName

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.41

hwPtpPortState

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.28

hwPtpOldPortState

hwPtpPortIfIndex

Impact on the System

The clock source may be switched.

Possible Causes

Cause 1: The attribute of the clock device on the network changes. As a result, the port status changes.

Cause 2: The link was faulty or the interface went down.

Procedure

1. Run the display ptp all command to check whether the interface is in the faulty state.

If yes, the link is faulty or the interface is Down. Go to Step 4.

If not, go to Step 2.

2. Run the display this interface and display ptp all config commands to check whether any command is used to change the clock attributes of the interface.

If the clock attribute changes, go to Step 4.

If not, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >