The port status changes. (hwPtpPortIfIndex=[hwPtpPortIfIndex], hwPtpPortName=[hwPtpPortName], hwPtpPortState=[hwPtpPortState], hwPtpOldPortState=[hwPtpOldPortState])
An alarm is generated when the port status changes.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
hwPtpPortStateChange |
Trap OID |
1.3.6.1.4.1.2011.5.25.187.5.1 |
MIB |
HUAWEI-PTP-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
hwPtpPortIfIndex |
Port index. |
hwPtpPortName |
Name of the port whose status changes. |
hwPtpPortState |
Current status of the port. |
hwPtpOldPortState |
Old status of a port. The value can be: master(1) slave(2) passive(3) listening(4) faulty(5) initializing(6) premaster(7) disabled(8) uncalibrated(9) |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.187.2.1.1.43 |
hwPtpPortName |
hwPtpPortIfIndex |
1.3.6.1.4.1.2011.5.25.187.2.1.1.41 |
hwPtpPortState |
hwPtpPortIfIndex |
1.3.6.1.4.1.2011.5.25.187.2.1.1.28 |
hwPtpOldPortState |
hwPtpPortIfIndex |
1. Run the display ptp all command to check whether the interface is in the faulty state.
If yes, the link is faulty or the interface is Down. Go to Step 4.
If not, go to Step 2.
2. Run the display this interface and display ptp all config commands to check whether any command is used to change the clock attributes of the interface.
If the clock attribute changes, go to Step 4.
If not, go to Step 3.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.