The synchronization server source of the client device is switched. (hwPtpAdaptiveOldTraceSource=[hwPtpAdaptiveOldTraceSource], hwPtpAdaptiveTraceSource=[hwPtpAdaptiveTraceSource])
The server source traced by the client is switched.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
PTPACRTRACESOURCE |
Trap OID |
1.3.6.1.4.1.2011.5.25.187.5.29 |
MIB |
HUAWEI-PTP-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
hwPtpAdaptiveOldTraceSource |
Historical synchronization server source of the client device. The options are as follows: local(0) server1(1) server2(2) |
hwPtpAdaptiveTraceSource |
Current synchronization server source of the client device. The options are as follows: local(0) server1(1) server2(2) |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.187.1.117 |
hwPtpAdaptiveOldTraceSource |
- |
1.3.6.1.4.1.2011.5.25.187.1.108 |
hwPtpAdaptiveTraceSource |
- |
1. Run the display ptp-adaptive all command to check the negotiation status between the client and the remote server.
If the negotiation status with a remote server is success, the negotiation with the remote server is successful, and no action is required.
If the negotiation status between the and all remote servers is error, run the ping command to check whether the links between the and remote servers are normal.
If so, go to Step 2.
If not, go to Step 3.
2. Run the display current-configuration command to check whether the clock configuration of the client is changed.
If yes, go to Step 5.
If no, go to Step 4.
3. Reconfigure the remote server. For details, see System Management > 1588v2 Configuration > Configuring 1588v2 ACR Clock Synchronization in the Configuration Guide. Check whether the fault is rectified.
If the alarm is cleared, go to Step 5.
If the alarm persists, go to Step 4.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.