The ptp standard time offset is abnormal. (hwPtpStandardTimeOffset=[hwPtpStandardTimeOffset], hwPtpAlarmThresholdStandardTimeOffset=[hwPtpAlarmThresholdStandardTimeOffset])
The PTP absolute time offset exceeded the threshold.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Error |
Mnemonic Code |
hwPtpStandardTimeOffsetOver |
Trap OID |
1.3.6.1.4.1.2011.5.25.187.5.35 |
MIB |
HUAWEI-PTP-MIB |
Alarm ID |
0x00F10062 |
Alarm Name |
hwPtpStandardTimeOffsetOver |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
PTP_1.3.6.1.4.1.2011.5.25.187.5.36 hwPtpStandardTimeOffsetOverResume |
Parameter | Description |
---|---|
hwPtpStandardTimeOffset |
The standard time offset. |
hwPtpAlarmThresholdStandardTimeOffset |
Threshold of the standard time offset. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.187.1.127 |
hwPtpStandardTimeOffset |
- |
1.3.6.1.4.1.2011.5.25.187.1.123 |
hwPtpAlarmThresholdStandardTimeOffset |
- |
1. Adjust the time of the current PTP time source to be the same as the external baseline time, and check whether the alarm is cleared.
2. Collect alarm, log, and configuration information, and contact Huawei technical support personnel.
3. End.