The hard pipe configured on the interface [interface-name] does not take effect.
The IP hard pipe configured on an interface did not take effect.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwXQoSHardPipeApplyFailAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.32.4.1.11.45 |
MIB |
HUAWEI-XQoS-MIB |
Alarm ID |
0x00F10106 |
Alarm Name |
hwXQoSHardPipeApplyFailAlarm |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.46 hwXQoSHardPipeApplyFailAlarmClear |
Parameter | Description |
---|---|
interface-name |
Hardpipe interface name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.32.4.1.23.1.1.1 |
hwXQoSHardPipeAlarmIfIndex |
hwXQoSHardPipeAlarmIfIndex |
The bandwidth of the IP hard pipe exceeded the value obtained by subtracting 20 Mbit/s from the smaller value of the interface bandwidth and port shaping value. For example, assume that the interface bandwidth is 1 Gbit/s, and the port shaping value is 900 Mbit/s. The value obtained by subtracting 20 Mbit/s from the smaller value of the interface bandwidth and port shaping value is 880 Mbit/s. If the bandwidth of the IP hard pipe exceeded 880 Mbit/s, an alarm is generated, and the IP hard pipe does not take effect.
1. Decrease the bandwidth of the IP hard pipe to be smaller than the value obtained by subtracting 20 Mbit/s from the smaller value of the interface bandwidth and port shaping value.
2. Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.