The hard pipe configured on the interface [interface-name] does not take effect.
The IP hard pipe configured on an interface did not take effect.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwXQoSHardPipeApplyFailAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.32.4.1.11.45 |
MIB |
HUAWEI-XQoS-MIB |
Alarm ID |
0x00F10106 |
Alarm Name |
hwXQoSHardPipeApplyFailAlarm |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.46 hwXQoSHardPipeApplyFailAlarmClear |
Parameter | Description |
---|---|
interface-name |
Hardpipe interface name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.32.4.1.23.1.1.1 |
hwXQoSHardPipeAlarmIfIndex |
hwXQoSHardPipeAlarmIfIndex |
1. Decrease the bandwidth of the IP hard pipe to be smaller than the value obtained by subtracting 20 Mbit/s from the smaller value of the interface bandwidth and port shaping value.
2. Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.