SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.1 hwSystemConfigError-144128

Trap Buffer Description

A system configuration error occurs. ( EntityTrapFaultID = [EntityTrapFaultID])

The system configuration is incorrect.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwSystemConfigError

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.11.1

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0D300004

Alarm Name

hwSystemConfigError

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume-144128

Trap Buffer Parameters

Parameter Description

EntityTrapFaultID

Trap error code:

  • 144128: The PAF version is inconsistent with the version of the startup software package.
  • 144129: The boards and subcards of the device are not inserted into the corresponding slots.
  • 144130: The versions of the active and standby main control boards are inconsistent.
  • 144133: The memory of the active main control board is inconsistent with that of the standby main control board.
  • 144134: The PTN startup mode does not match the mode selected during license activation.

VB Parameters

None

Impact on the System

  • If the PAF version is inconsistent with the version of the startup software package, the PAF file carried in the startup software package is started.
  • When the versions of the active and standby main control boards are inconsistent, the standby main control board cannot be started.
  • If the PTN startup mode does not match the mode selected during license activation, services in the mode selected during license activation may not take effect.

Possible Causes

The version in the PAF file is inconsistent with that of the startup software package.

Procedure

The PAF version was inconsistent with the version of the startup software package.

1. Replace the PAF file with a PAF file of the same version as the system software package. Run the startup paf command to set the PAF file as the one to be loaded at the next startup. Then, run the reboot command to restart the device.

  • If the alarm is cleared, go to Step 3.
  • If the alarm persists, go to Step 2.

2. Collect alarm and configuration information, and contact technical support personnel.

3. No further action is required.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >