TRUNK_1.3.6.1.4.1.2011.5.25.41.3.9 hwExtLinkDown

Trap Buffer Description

The link status of the trunk member interface turned to DOWN.(ifIndex=[ifIndex], ifAdminStatus=[ifAdminStatus], ifOperStatus=[ifOperStatus], ifDescr=[ifDescr], hwIFExtPhyStatus=[hwIFExtPhyStatus], hwIFExtMemberOf=[hwIFExtMemberOf])

A trunk member interface went Down.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Critical

Mnemonic Code

TRUNK_MEM_LINKDOWN

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.9

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

ifIndex

Index of a trunk member interface.

ifAdminStatus

Administration status of a trunk member interface.

ifOperStatus

Operating status of a trunk member interface.

ifDescr

Name of a trunk member interface.

hwIFExtPhyStatus

Physical status of a trunk member interface.

hwIFExtMemberOf

Name of the trunk interface to which the member interface belongs.

hwTrunkIndex

Index of the trunk interface to which the member interface belongs.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.2.1.2.2.1.1

ifIndex

ifIndex

1.3.6.1.2.1.2.2.1.7

ifAdminStatus

ifIndex

1.3.6.1.2.1.2.2.1.8

ifOperStatus

ifIndex

1.3.6.1.2.1.2.2.1.2

ifDescr

ifIndex

1.3.6.1.4.1.2011.5.25.41.1.1.2

hwIFExtPhyStatus

-

1.3.6.1.4.1.2011.5.25.41.1.1.3

hwIFExtMemberOf

-

Impact on the System

The member interface cannot forward packets, and services on the interface will be interrupted.

Possible Causes

Cause 1: The interface was shut down, and its inserted physical link was disconnected. Cause 2: The link-layer protocol status of the interface became Down.

Procedure

  • Cause 1: The interface was shut down, and its inserted physical link was disconnected.

1. Run the display this command in the interface view to check whether the trunk member interface is shut down.

  • If the interface is shut down, go to Step 2.
  • If the interface is not shut down, go to Step 3.

2. Run the undo shutdown command in the interface view to enable the interface and then check whether the alarm is cleared. If the alarm persists, go to Step 3.

3. Check whether the physical connection of the interface is proper (for example, whether the network cable is properly connected and optical module is properly inserted).

  • If the physical connection is proper, go to Step 5.
  • If the physical connection is improper, go to Step 4.

4. Correctly connect the physical link and check whether the alarm is cleared. If the alarm persists, go to Step 5.

5. Collect alarm information and configuration information, and then contact technical support personnel.

  • Cause 2: The link-layer protocol status of the interface became Down.

1. Run the display this command in the interface view to check whether the trunk member interface is shut down.

  • If the interface is shut down, go to Step 2.
  • If the interface is not shut down, go to Step 3.

2. Run the undo shutdown command in the interface view to enable the interface and then check whether the alarm is cleared. If the alarm persists, go to Step 3.

3. Troubleshoot the Down fault of the link-layer protocol. If the link-layer protocol still cannot go Up, go to Step 4.

4. Collect alarm information and configuration information, and then contact technical support personnel.