VFS_1.3.6.1.4.1.2011.6.9.1.3.3 hwFlhSyncFailNotification

Trap Buffer Description

Failed to copy file by hwFlhSyncTable with FlhSyncIndex [FlhSyncIndex], FlhSyncSrcFile [FlhSyncSrcFile], FlhSyncDstFile [FlhSyncDstFile].

Failed to copy files using hwFlhSyncTable of HUAWEI-FLASH-MAN-MIB.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Error

Mnemonic Code

VFM_FLHSYNC_FAIL

Trap OID

1.3.6.1.4.1.2011.6.9.1.3.3

MIB

-

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

FlhSyncIndex

Index of the file to be copied.

FlhSyncSrcFile

Source file.

FlhSyncDstFile

Target file.

VB Parameters

None

Impact on the System

Failed to copy the file.

Possible Causes

Copying files through HUAWEI-FLASH-MAN-MIB failed.

Procedure

1. Check whether the entered file name is correct, and the disk and storage medium have sufficient storage space. Collect log information and configuration information, and then contact technical support personnel. If the entered file name is correct, and the disk and storage medium have sufficient storage space.