oam-bind ingress efm interface egress cfm md ma

Function

The oam-bind ingress efm interface egress cfm md ma command configures Ethernet in the First Mile (EFM) to send fault messages to Ethernet connectivity fault management (CFM).

The undo oam-bind ingress efm interface egress cfm md ma command disables EFM from sending fault messages to Ethernet CFM.

By default, EFM is disabled from sending fault messages to Ethernet CFM.

Format

oam-bind ingress efm interface { interface-name | interface-type interface-number } egress cfm md md-name ma ma-name

undo oam-bind ingress efm interface { interface-name | interface-type interface-number } egress cfm md md-name ma ma-name

Parameters

Parameter Description Value
interface-type

Specifies the type of an Ethernet interface. The interface must be enabled with EFM.

-

interface-number

Specifies the number of an Ethernet interface. The interface must be enabled with EFM.

-

md-name

Specifies the name of an MD.

The value is a string of 1 to 43 case-sensitive characters. Question marks (?), hyphens (-) are not supported.

ma-name

Specifies the name of an MA.

The value is a string of 1 to 43 case-sensitive characters. Question marks (?), hyphens (-) are not supported. The total length of MA and MD names must be no greater than 44 characters.

Views

OAM management view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
oammgr write

Usage Guidelines

Usage Scenario

If EFM is deployed on one side of a device and CFM is deployed on the other side of the device, association between EFM and CFM can be configured on the device. This allows EFM and CFM to notify each other of faults and ensures reliable service transmission.

Association between EFM and CFM is bidirectional. The details are as follows:

  • If EFM detects a link fault, it will notify CFM of the fault.
  • If CFM detects a link fault, it will notify EFM of the fault.

Prerequisites

MDs and MAs have been created and EFM has been enabled on specified interfaces.

Example

# Configure EFM to send fault messages to Ethernet CFM through GE 0/1/17.
<HUAWEI> system-view
[~HUAWEI] efm enable
[*HUAWEI] interface GigabitEthernet0/1/17
[*HUAWEI-GigabitEthernet0/1/17] efm enable
[*HUAWEI-GigabitEthernet0/1/17] quit
[*HUAWEI] cfm enable
[*HUAWEI] cfm md mdcustomer
[*HUAWEI-md-mdcustomer] ma macustomer
[*HUAWEI-md-mdcustomer-ma-macustomer] oam-mgr
[*HUAWEI-oam-mgr] oam-bind ingress efm interface GigabitEthernet 0/1/17 egress cfm md mdcustomer ma macustomer
Copyright © Huawei Technologies Co., Ltd.