The efm error-frame period command configures a period during which errored frames are detected on an interface.
The undo efm error-frame period command restores the default period.
The default period is 1 second.
Layer 2 100GE interface view, 100GE interface view, Layer 2 10GE interface view, 10GE interface view, 25GE-L2 view, 25GE interface view, 400GE-L2 view, 400GE interface view, Layer 2 40GE interface view, 40GE interface view, Layer 2 50GE interface view, 50GE interface view, FlexE interface view, Layer 2 GE interface view, GE optical interface view, GE interface view, GE electrical interface view
Usage Scenario
After the efm error-frame notification enable command is run, you can run the efm error-frame period command to specify a period during which errored frames are detected. When the number of detected errored frames within the period specified by period parameter reaches or exceeds a specified threshold, the local device generates an alarm and notifies the peer device of the alarm event.
Prerequisites
EFM OAM has been globally enabled using the efm enable command in the system view.
Configuration Impact
After a local interface is enabled to report detected errored frames, the local device generates a threshold-crossing event of errored frames and reports the event to the remote device if the number of errored frames detected on the interface reaches or exceeds the specified threshold.
Precautions
If the link quality is poor and the period during which errored frames are detected is too short, the local device may frequently send the threshold-crossing event of errored frames to the remote device. If the specified period is too long, link monitoring may be of little effect. Therefore, the period during which errored frames are detected must be set properly based on the link quality.