The mpls oam bidirectional-tunnel lost-measure single-ended proactive command enables proactive single-ended frame loss measurement (LM) for a bidirectional LSP.
The undo mpls oam bidirectional-tunnel lost-measure single-ended proactive command deletes the configuration.
By default, proactive single-ended frame LM is disabled for a bidirectional LSP.
Parameter | Description | Value |
---|---|---|
exp exp-value |
Specifies a priority for LMMs. |
The value is an integer ranging from 0 to 7. A larger value indicates a higher priority. The default value is 7. |
tunnel-type tunnel-number |
Specifies the tunnel type and number. |
- |
tunnel-name |
Specifies the tunnel name. |
the value is a string, length is no more than 63 |
Usage Scenario
Packet LM is a performance monitoring function provided by MPLS-TP. Single-ended frame LM is implemented on two MEPs over an LSP. The measurement results include the following data:
Prerequisites
Precautions
<HUAWEI> system-view [*HUAWEI] mpls [*HUAWEI-mpls] mpls te [*HUAWEI-mpls] mpls oam [*HUAWEI-mpls] quit [*HUAWEI] interface tunnel 10 [*HUAWEI-Tunnel10] tunnel-protocol mpls te [*HUAWEI-Tunnel10] mpls te signal-protocol cr-static [*HUAWEI-Tunnel10] mpls te bidirectional [*HUAWEI-Tunnel10] quit [*HUAWEI] mpls-oam [*HUAWEI-mpls-oam] mpls oam bidirectional-tunnel Tunnel 10 type ffd frequency 3 [*HUAWEI-mpls-oam] mpls oam bidirectional-tunnel lost-measure single-ended proactive exp 1 Tunnel 10