dcn ospf timer poll (DCN view)

Function

The dcn ospf timer poll command sets the interval at which DCN interfaces of a specified interface sends poll Hello packets on a non-broadcast multiple access (NBMA) network.

The undo dcn ospf timer poll command restores the default interval.

The default interval is 120 seconds.

Format

dcn ospf timer poll interval

undo dcn ospf timer poll

Parameters

Parameter Description Value
interval

Specifies the interval at which poll Hello packets are sent.

The value is an integer ranging from 1 to 3600, in seconds.

Views

DCN view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
dcn write

Usage Guidelines

Usage Scenario

On an NBMA network, to enable a device to send poll Hello packets at a specified interval after the device's neighbor goes Down, run the dcn ospf timer poll command.

Prerequisites

The DCN feature has been enabled globally using the dcn (interface view) command in the interface view, or DCN communication through sub-interfaces 4094 has been enabled using the dcn mode vlan command in the GE interface view.

Precautions

The interval value specified in the dcn ospf timer poll command must be at least four times as long as interval specified in the dcn ospf timer hello command.

If the dcn ospf timer poll command is run in the DCN view, the interval at which poll Hello packets are sent is set for all DCN interfaces.

In VS mode, this command is supported only by the admin VS.

Example

# Configure the DCN serial interfaces send poll Hello packets every 130 seconds.
<HUAWEI> system-view
[~HUAWEI] dcn
[~HUAWEI-dcn] dcn ospf timer poll 130
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >