Parameter | Description | Value |
---|---|---|
interface interface-type interface-number |
Specifies the type and number of an interface. |
- |
vsi vsi-name |
Specifies the name of a specified VSI instance. |
The value is a string of 1 to 31 case-sensitive characters, spaces not supported. When double quotation marks are used around the string, spaces are allowed in the string. |
pw pw-name |
Specifies the name of a specified PW. |
The value is a string of 1 to 15 case-sensitive characters, spaces not supported. When double quotation marks are used around the string, spaces are allowed in the string. |
Usage Scenario
Before collecting STP statistics on an interface within a certain period, run the reset stp statistics command to clear existing statistics.
When you run the reset stp statistics command: