set cpu-reliability

Function

The set cpu-reliability command specifies the level-1 alarm threshold, level-1 clear alarm threshold, level-2 alarm threshold, level-2 clear alarm threshold, and detection period of CPU overload.

The undo set cpu-reliability command restores the default configuration.

By default, the level-1 alarm threshold, level-1 clear alarm threshold, level-2 alarm threshold, level-2 clear alarm threshold, and detection period of CPU overload are 60, 50, 80, 70, and 60, respectively.

Format

set cpu-reliability first-recover first-recover-value first-alarm first-alarm-value second-recover second-recover-value second-alarm second-alarm-value period period-value [ slot slot-id ]

undo set cpu-reliability [ slot slot-id ]

Parameters

Parameter Description Value
first-alarm first-alarm-value

Specifies a level-1 alarm threshold.

The value is an integer ranging from 2 to 97. The default value is 60.

second-recover second-recover-value

Specifies a level-2 clear alarm threshold.

The value is an integer ranging from 3 to 98. The default value is 70.

second-alarm second-alarm-value

Specifies a level-2 alarm threshold.

The value is an integer ranging from 4 to 99. The default value is 80.

period period-value

Specifies a detection period.

The value is an integer ranging from 30 to 3600, in seconds. The default value is 60.

slot slot-id

Specifies the level-1 and level-2 alarm thresholds of CPU overload on the slave control board.

-

first-recover first-recover-value

Specifies a level-1 clear alarm threshold.

The value is an integer ranging from 1 to 96. The default value is 50.

Views

System view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
diagnose write

Usage Guidelines

Usage Scenario

To configure the level-1 alarm threshold, level-1 clear alarm threshold, level-2 alarm threshold, level-2 clear alarm threshold, and detection period of CPU overload, run the set cpu-reliability command based on deployed services.

Precautions

This command is supported only on the admin VS.

Example

# Configure the level-1 alarm threshold, level-1 clear alarm threshold, level-2 alarm threshold, level-2 clear alarm threshold, and detection period of CPU overload on the interface board in slot 1 as 30, 10, 60, 50, and 1000, respectively.
<HUAWEI> system-view
[~HUAWEI] set cpu-reliability first-recover 10 first-alarm 30 second-recover 50 second-alarm 60 period 1000 slot 1