probe-count (UDP Jitter test instance)

Function

The probe-count command sets the number of probes for an NQA test instance of UDP Jitter test.

The undo probe-count command restores the default number of probes.

By default, the number of probes is 3.

Format

probe-count number

undo probe-count

Parameters

Parameter Description Value
number

Specifies the number of probes in a test instance.

The value is an integer ranging from 1 to 15.

Views

NQA view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
sla write

Usage Guidelines

Usage Scenario

On unreliable networks, to set the number of probes for an NQA test instance, run the probe-count command. Then, you can monitor network quality by analyzing the probe statistics.

Configuration Impact

In a jitter test instance, the product of the number of the jitter tests specified using the probe-count command multiplied by the number of the test packets specified using the jitter-packetnum command cannot be greater than 3000.

If the number of probes has been configured for an NQA test instance, running the probe-count command again overrides the previous configuration.

Precautions

If parameters need to be changed during the running of the test instance, the system prompts you whether to terminate the test instance. Press "Y" or "N" as required.

  • If you press "Y", the test instance is terminated and parameters changed. The settings take effect after being committed. To restart the test instance, run the start command.
  • If you press "N", the test instance keeps running, and the parameters fail to be modified.

Example

# Set the number of the probes for the test instance named user test to 15.
<HUAWEI> system-view
[~HUAWEI] nqa test-instance user test
[*HUAWEI-nqa-user-test] test-type jitter
[*HUAWEI-nqa-user-test] probe-count 15
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.