timestamp-unit (UDP jitter test instance)

Function

The timestamp-unit command sets the unit of timestamps for an NQA UDP jitter test instance.

The undo timestamp-unit command restores the default unit.

The unit of timestamp for NQA test instance is millisecond by default.

Format

timestamp-unit microsecond

timestamp-unit millisecond

undo timestamp-unit microsecond

Parameters

Parameter Description Value
millisecond

Sets the unit of timestamps for an NQA test instance to millisecond.

-

microsecond

Sets the unit of timestamps for an NQA test instance to microsecond.

-

Views

NQA view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
sla write

Usage Guidelines

Usage Scenario

After you enable an interface board to send packets, to set the unit of timestamp for NQA test instances, run the timestamp-unit command.

Prerequisites

The hardware-based enable command has been run to enable the hardware forwarding function before the timestamp-unit microsecond command is run.

Example

# Set the unit of timestamp for NQA test instance to microsecond.
<HUAWEI> system-view
[~HUAWEI] nqa test-instance user test
[*HUAWEI-nqa-user-test] test-type jitter
[*HUAWEI-nqa-user-test] timestamp-unit millisecond
Copyright © Huawei Technologies Co., Ltd.