upgrade rollback

Function

The upgrade rollback command enables the version rollback function and sets a timeout period for version rollback.

The undo upgrade rollback command disables the version rollback function during version upgrade.

By default, the version rollback function is disabled.

Format

upgrade rollback enable rollback-timer time-value

undo upgrade rollback

Parameters

Parameter Description Value
time-value

Specifies a timeout period for a rollback timer.

The value is an integer ranging from 10 to 360, in minutes.

Views

User view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
upgrade execute

Usage Guidelines

Usage Scenario

If you need to cancel the version upgrade being performed for some reason (for example, a new startup file was damaged), you can run the upgrade rollback command to perform version rollback to restore the version being upgraded to the original version.

After the version rollback function is enabled and the system package is restarted, the system will perform a version rollback to roll back the system package and patch if no users successfully log in to the device in a specified period of time.

If the version rollback function is disabled, the system will not perform version rollback whether any users successfully log in to the device in a specified period of time.

By default, the version rollback function is disabled. After the version rollback function is performed, the system restores to the default setting.

Configuration Impact

After the command is run, the rollback timer of the current system will be reset.

Precautions

If users successfully log in to the device, the system automatically cancels the timeout period for version rollback.

The items that can be rolled back include system software and patch files.

In VS mode, this command is supported only by the admin VS

Example

# Set a rollback timer for the current version upgrade.
<HUAWEI> upgrade rollback enable rollback-timer 60
Info: The upgrade rollback function is enabled. The limit time is 20 minutes.
If no User cancels the function, the master MPU will restart by the bootfile cfcard:/VRPV800RxxxCxxBxxx.cc.The slave MPU will restart by the bootfile cfcard:/VRPV800RxxxCxxBxxx.cc.
# Disable the version rollback function during version upgrade.
<HUAWEI> undo upgrade rollback
Info: The state of upgrade rollback is disable.
Copyright © Huawei Technologies Co., Ltd.