access-limit(AAA view)

Function

The access-limit command configures the maximum number of users who are allowed to access the LNS.

The undo access-limit command cancels the configuration.

By default, a maximum of 32768 users are allowed to access an LNS.

This command is supported only on the NetEngine 8000 F1A.

Format

access-limit max-number access-type lns

undo access-limit

Parameters

Parameter Description Value
max-number

Specifies the maximum number of access users.

The value is an integer that ranges from 0 to 65536.

access-type

Service's type.

-

lns

Specifies the LNS access.

-

Views

AAA view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
l2tp write

Usage Guidelines

Usage Scenario

This command can be used to restrict the number of users that access the LNS.

Configuration Impact

If the set maximum number of users that access the LNS is reached, the additional access users will be denied.

Precautions

In VS mode, this command is supported only by the admin VS.

Example

# Set the maximum number of users who are allowed to access the LNS to 100.
<HUAWEI> system-view
[~HUAWEI] aaa
[*HUAWEI-aaa] access-limit 100 access-type lns
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >