suppression alarm-name

Function

The suppression alarm-name command configures a suppression period for an alarm.

The undo suppression alarm-vvname command deletes a suppression period.

By default, the suppression period for reporting an alarm is 3s, and the suppression period for clearing an alarm is 10s.

Format

suppression alarm-name alarm-name { cause-period cause-seconds | clear-period clear-seconds }

undo suppression alarm-name alarm-name cause-period

undo suppression alarm-name alarm-name clear-period

Parameters

Parameter Description Value
alarm-name

Specifies the name of an alarm. This alarm must exist.

The value is a string of 1 to 63 characters, spaces not supported.

cause-period cause-seconds

Specifies the period after which an alarm is generated. If an alarm is repeatedly reported during cause-period, the system does not report the alarm until cause-period expires.

The value is an integer that ranges from 0 to 600, in seconds.

clear-period clear-seconds

Specifies the period after which an alarm is cleared. If a clear alarm is repeatedly reported during clear-period, the system reports the clear alarm until cause-period expires.

The value is an integer that ranges from 0 to 600, in seconds.

Views

Alarm management view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
fault-mgr write

Usage Guidelines

Usage Scenario

You can configure a suppression period to prevent an alarm from being frequently reported.

Alarms for each application can be assigned a specific suppression period. Alarm suppression can be disabled for some alarms generated for hardware and devices.

Configuration Impact

If the suppression period is set too short, you do not give full play to the suppression effect; if the suppression period is set too long, faults cannot be detected in time. For most alarms, the default suppression period is recommended. You can set the suppression period to 0s for alarms that must be immediately reported, such as alarms about hardware and ambient environments. To ensure stable alarm functions in flapping situations, some services have an extra alarm clearance suppression period. For this type of service, after this command is run to configure the alarm clearance suppression period(tens of seconds), you need to wait for the extra suppression period to allow alarm clearance to take effect.

Example

# Set the suppression period for reporting the alarm named linkDown to 5s and the suppression period for clearing the alarm to 15s.
<HUAWEI> system-view
[~HUAWEI] alarm
[~HUAWEI-alarm] suppression alarm-name linkDown cause-period 5
[*HUAWEI-alarm] suppression alarm-name linkDown clear-period 15
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.