backup up-link track monitor-group

Function

The backup up-link track monitor-group command configures a vBRAS-UP to track an interface monitoring group, detecting network-side link faults.

The undo backup up-link track monitor-group command restores the default configuration.

By default, a vBRAS-UP is not configured to track an interface monitoring group.

This command is supported only on the NetEngine 8000 F1A.

Format

backup up-link track monitor-group group-name trigger-down-weight down-weight-value

undo backup up-link track monitor-group group-name [ trigger-down-weight down-weight-value ]

Parameters

Parameter Description Value
trigger-down-weight down-weight-value

Specifies an interface weight for reporting a network-side fault.

The value is an integer ranging from 1 to 32000.

The value cannot be greater than the weight sum of all Down interfaces in an interface monitoring group.

monitor-group group-name

Specifies the name of an interface monitoring group.

The value is a string of 1 to 31 characters.

Views

CU-agent view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
bras-control write

Usage Guidelines

Usage Scenario

In a CU separation UP dual-device hot backup scenario, if a network-side interface goes Down, the vBRAS-CP cannot detect the Down event and therefore do not switch traffic to the secondary link. As a result, traffic is overloaded or lost. To enable the vBRAS-CP to detect network-side faults, configure an interface monitoring group, add network-side interfaces to the interface monitoring group, and run the backup up-link track monitor-group command to configure a vBRAS-UP to track the interface monitoring group. When detecting an interface fault, the vBRAS-UP reports the fault to the vBRAS-CP, triggering a master/backup switchover.

Prerequisites

An interface monitoring group has been created using the monitor-group command in the system view.

Configuration Impact

After the backup up-link track monitor-group command is run, user-side services are switched to the secondary link if the weight sum of all Down interfaces in a specified interface monitoring group reaches the value specified by.

Precautions

In VS mode, this command is supported only by the admin VS.

Example

# Configure a vBRAS-UP to track an interface monitoring group named test.
<HUAWEI> system-view
[~HUAWEI] cu-agent
[~HUAWEI-cu-agent] backup up-link track monitor-group test trigger-down-weight 20