clock freq-deviation recover

Function

The clock freq-deviation recover command restores the frequency deviation status of a clock source and adds it to the clock source list on the interface board again.

By default, no recovery operation is performed.

Format

clock freq-deviation recover

Parameters

None

Views

100GE interface view, 10G LAN interface view, 400GE interface view, 40GE interface view, 50GE interface view, FlexE-100G interface view, FlexE-400G interface view, FlexE-50G interface view, GE optical interface view, GE electrical interface view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
clksync write

Usage Guidelines

Usage Scenario

After the clock freq-deviation-detect enable and clock board-freq-switch enable commands are used to enable frequency detection and frequency deviation-triggered clock source switching, if the frequency deviation of a clock source is detected abnormal, the clock source is deleted from the clock source list of the corresponding interface board. To restore the frequency deviation of the clock source and add it to the clock source list on the interface board again, run the clock freq-deviation recover command.

In VS mode, this command is supported only by the admin VS.

Example

# Restore the frequency deviation of the clock source of the interface board and add the clock source to the clock source list on the interface board again.
<HUAWEI> system-view
[~HUAWEI] interface GigabitEthernet 0/1/0
[~HUAWEI-GigabitEthernet0/1/0 ] clock freq-deviation recover
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >