display error-down recovery

Function

The display error-down recovery command displays information about the interface in the error-down state, including the interface name, cause of the error-down event, delay for the transition from Down to Up, and remaining time for the Up event.

Format

display error-down recovery [ interface { interface-name | interface-type interface-number } ]

Parameters

Parameter Description Value
interface interface-type interface-number

Specifies the type and number of an interface.

The value is a string of 1 to 63 case-sensitive characters, spaces not supported.

interface-name

Specifies the name of an interface.

The value is a string of 1 to 63 case-sensitive characters, spaces not supported.

Views

All views

Default Level

1: Monitoring level

Task Name and Operations

Task Name Operations
interface-mgr read

Usage Guidelines

Usage Scenario

The auto recovery function is configured and the delay for the transition from Down to Up is set on an interface using the error-down auto-recovery command. If the interface is now in the error-down state, run the display error-down recovery command to view the remaining time for an Up event.

An interface enters the error-down state after being shut down due to an error.

Prerequisites

The auto recovery function has been configured on an interface using the error-down auto-recovery command.

Configuration Impact

If interface is not configured in this command, the system displays information about all interfaces in the error-down state.

Example

The actual command output varies according to the device. The command output here is only an example.

# Display the delay for the transition from Down to Up and the remaining time for the Up event.
<HUAWEI> display error-down recovery
interface                    error-down cause         recovery   remainder 
                                                      time(sec)  time(sec)
----------------------------------------------------------------------------
GigabitEthernet0/1/2         bpdu-protection          30          10
Table 1 Description of the display error-down recovery command output
Item Description
error-down cause

Cause of the error-down event.

recovery time

Delay (in seconds) for a transition from Down to Up.

If the auto recovery function is not configured, it needs to recovery from Down to Up using undo shutdown command. In this case, hyphens (--) are displayed in this field.

interface

Port name.

remainder time

Remaining time for an Up event.

If the auto recovery function is not configured, it needs to recovery from Down to Up using undo shutdown command. In this case, hyphens (--) are displayed in this field.

Copyright © Huawei Technologies Co., Ltd.