The display damp-interface brief command displays suppression status of a flapping physical interface.
Usage Scenario
To check the suppression status of a flapping interface, run the display damp-interface brief command. The command output facilitates status monitoring and fault diagnosis. The command output provides a basis for statistics collection and interface troubleshooting.
Precautions
If status flapping suppression is configured globally, the display damp-interface brief command output displays the suppression status and relevant statistics of all physical interfaces that do not have the damp-interface ignore-global command configuration.
If the damp-interface enable command is not run in the global view, the display damp-interface and display damp-interface brief command display the suppression status and statistics of a flapping interface that is suppressed.The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> display damp-interface brief Interface Suppress status GE0/1/16 unsuppressed GE0/1/17 suppressed GE0/1/18 unsuppressed GE0/1/19 unsuppressed GE0/1/20 unsuppressed GE0/1/21 unsuppressed
Item | Description |
---|---|
Interface | Name and number of an interface. |
Suppress status | Suppression status of the interface. The value can be:
|