display isis avoid-microloop information

Function

The display isis avoid-microloop information command displays anti-micro-loop information.

Format

display isis [ process-id ] avoid-microloop information [ ipv6 ] [ level-1 | level-2 ] [ systemid systemid ]

display isis [ process-id ] avoid-microloop information [ ipv6 ] [ level-1 | level-2 ] [ systemid systemid ] flex-algo flex-algo-id

Parameters

Parameter Description Value
process-id

Specifies the ID of a process whose anti-micro-loop information is to be displayed.

If this parameter is not configured, anti-micro-loop information of all processes is displayed.

The value is an integer ranging from 1 to 4294967295.

ipv6

Displays anti-micro-loop information in IPv6 topology.

-

level-1

Displays anti-micro-loop information on nodes in Level-1 areas.

-

level-2

Displays anti-micro-loop information on nodes in Level-2 areas.

If no level is specified, anti-micro-loop information of nodes in all areas is displayed.

-

systemid systemid

Specifies the system ID or pseudo node ID.

The value is a hexadecimal integer in the format of XXXX.XXXX.XXXX.

flex-algo flex-algo-id

Specifies the Flexible Algorithm ID.

The value is an integer ranging from 128 to 255.

Views

All views

Default Level

1: Monitoring level

Task Name and Operations

Task Name Operations
isis read

Usage Guidelines

Usage Scenario

After the SR anti-micro-loop function is enabled, run the display isis avoid-microloop information command to view anti-micro-loop information on nodes. The command output contains the anti-micro-loop type, cause for failures, and date and time when the device entered and exited the anti-microloop state.

Example

The actual command output varies according to the device. The command output here is only an example.

# After the SR anti-micro-loop function is enabled, view anti-micro-loop information on nodes. The command output contains the anti-micro-loop type, cause for failures, and date and time when the device entered and exited the anti-microloop state.
<HUAWEI> display isis avoid-microloop information flex-algo 128
                     Avoid Microloop Information For ISIS(1)
                     --------------------------------------
                      Level-1 Avoid Microloop Information

DestNode :0000.0000.0002
Avoid-Microloop-Technology :segment-routing
Failed-Reason :-
More-Recent-Details:
Entry time :08:27:23.465,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000

DestNode :0000.0000.0004
Avoid-Microloop-Technology :segment-routing
Failed-Reason :-
More-Recent-Details:
Entry time :08:27:23.465,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000

                      Level-2 Avoid Microloop Information

DestNode :0000.0000.0002
Avoid-Microloop-Technology :segment-routing
Failed-Reason :-
More-Recent-Details:
Entry time :08:27:23.467,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000

DestNode :0000.0000.0004
Avoid-Microloop-Technology :segment-routing
Failed-Reason :-
More-Recent-Details:
Entry time :08:27:23.466,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000
Entry time :00:00:00.000,  Exit time :00:00:00.000
# Display anti-micro-loop information on nodes.
<HUAWEI> display isis 1 avoid-microloop information level-1
                     Avoid Microloop Information For ISIS(1)
                     --------------------------------------
                      Level-1 Avoid Microloop Information  
   
DestNode :0000.0000.0002  
Avoid-Microloop-Technology :segment-routing
Failed-Reason :Stack length exceeds maximum (9 layers).
More-Recent-Details:
Entry time :00:00:17.012 ,  Exit time :00:00:20.120
Entry time :00:00:10.019 ,  Exit time :00:00:12.330
Entry time :00:00:01.022 ,  Exit time :00:00:03.160
Table 1 Description of the display isis avoid-microloop information command output
Item Description
DestNode

Destination node.

Avoid-Microloop-Technology

Anti-micro-loop type.

Failed-Reason

Cause for a failure to prevent a micro loop.

Entry time

Time for entering anti-microloop.

Exit time

Time for exiting anti-microloop.

More-Recent-Details

Detailed information:

  • Entry time: Date and time when the device entered the anti-microloop state.
  • Exit time: Date and time when the device exited the anti-microloop state.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >