Usage Scenario
To view E-labels of interface boards and the backplane of a device, run the display elabel command.
Prerequisites
Ensure that the backplane provides a storage function before running the display elabel backplane command.
Precautions
In VS mode, this command is supported only by the admin VS.
If you run the display elabel command without specifying slotid, E-labels for all boards and optical modules on a chassis are displayed; if slotid is specified, the E-label of a board or optical module in a specified slot is displayed.The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> display elabel brief Elabel brief information: -------------------------------------------------------------------------------- Slot # BoardType BarCode Description -------------------------------------------------------------------------------- IPU 1 *******UA1C0 ****UWU2019091103 *** FAN * ***NCBA ****PJGW0K5001335 …
<HUAWEI> display elabel 1 2020-04-30 10:48:30.919 [Slot_1] /$[Board Integration Version] /$BoardIntegrationVersion=3.0 [Main_Board_1] /$[ArchivesInfo Version] /$ArchivesInfoVersion=3.0 [Board Properties] BoardType=****E2VBC0 BarCode=033GDR10KC000*** Item=03033*** Description=Finished Board,**** Manufactured=2020-01-13 VendorName=Huawei IssueNumber=00 CLEICode= BOM= Model=****0E5XMF94 ExInfo=HlevelSN:0815 /$ElabelVersion=4.0
Item | Description |
---|---|
Slot | Slot ID. |
BoardType | Type of a Field Replaceable Unit (FRU):
|
BarCode | Bar code. |
Description | Description. |
Description | Silk screen. |
BoardIntegrationVersion | Board integration version number. |
ArchivesInfoVersion | Issuing number of an archive. |
Item | BOM code. |
Manufactured | Manufacturing date. |
VendorName | Vendor name. |
IssueNumber | Issue number. |
CLEICode | FRU's CLEI code. |
BOM | Sales BOM code. |
Model | External model. |
ExInfo | Extended information. |
ElabelVersion | Electronic label version. |