The display ipsec performance command displays the IPsec performance indicators of a board.
This command is supported only on the NetEngine 8000 F1A.
Usage Scenario
To query the IPsec performance indicators of a board, such as the CPU usage of the board and encryption and decryption performance, run the display ipsec performance command.
The packet length shown in the command output indicates the length of the IPsec packet excluding the Layer 2 header.The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> display ipsec performance slot 1 Slot 1: vcpu usage: 0% encrypt/decrypt performance: packet size | pps | kbps | total | 0/0 | 0/0 |
Item | Description |
---|---|
Slot 1 | Slot 1. |
vcpu usage | Maximum usage of this CPU among all forwarding threads. |
encrypt/decrypt performance | Encryption/decryption performance. |
packet size | Packet length range. |
pps | Number of encrypted/decrypted packets within 1s. |
kbps | Number of encrypted/decrypted kbits within 1s. |