The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> display alarm active root verbose
Sequence : 6
AlarmId : 0xD300007 AlarmName : hwStorageUtilizationRisingAlarm
AlarmType : quality_of_service Severity : Major State : active
RootKindFlag: RootCause
StartTime : 2020-01-18 09:13:16
Description : The storage usage exceeded the pre-set overload threshold.(TrapSeverity=4, ProbableCause=75265, EventType=3, PhysicalIndex=17956865, PhysicalName=xxxx, RelativeResource=cfcard, UsageType=5, SubIndex=1, UsageValue=89, Unit=1, UsageThreshold=85)
<HUAWEI> display alarm active root
1:Critical 2:Major 3:Minor 4:Warning
--------------------------------------------------------------------------------
Sequence AlarmId Level Date Time Description
--------------------------------------------------------------------------------
6 0xD300007 2 2020-01-18 The storage usage exceeded the pre-set ov
09:13:16 erload threshold.(TrapSeverity=4, Probabl
eCause=75265, EventType=3, PhysicalIndex=
17956865, PhysicalName=xxxx, Relat
iveResource=cfcard, UsageType=5, SubIndex
=1, UsageValue=89, Unit=1, UsageThreshold
=85)
--------------------------------------------------------------------------------
Item | Description |
---|---|
Sequence | Alarm sequence number. |
AlarmId | Alarm ID. |
AlarmName | Alarm name. |
AlarmType | Type of a service for which an alarm is generated. |
Severity | Alarm severity. |
State | Alarm status:
|
StartTime | Date and time when an alarm was generated. |
Description | Alarm description. |
Level | Alarm severity. |
Date Time | Date and time when an alarm was generated. |
RootKindFlag | Alarm generation type:
|